TMDT2-30_STANDART YÜZEY PROBU SKF

TKTL SeriesSKF Infrared thermometers
؏؏SKF offers a wide range of portable, lightweight and easy-to-use infrared thermometers for thermal inspections. These portable tools help you to detect temperature differences in technical and non-technical applications, this in order to perceive information on abnormalities in operating.SKF Infrared thermometers are fitted with multiple lasers which helps you to easy and more accurate target the object. The TKTL 21, 31 and 40 also offer you the option of measuring temperatures via a temperature probe. The TKTL 40 offers you the possibility of data logging and allows pictures and videos with all measurement information to be taken.SKF Infrared thermometersTKTL SeriesTKTL 11Basic infrared thermometer! LCD colour display! 8 laser targeting! Fixed emissivity! High accuracy! Fast response time! DS ratio of 16:1TKTL 21Advanced infrared thermometer! LCD colour display! 8 laser targeting! Type-K thermocouple probe! Adjustable emissivity! High accuracy! Fast response time! DS ratio of 30:1TKTL 31High performance infrared thermometer! LCD monochrome display, backlit! Dual laser targeting! Type-K thermocouple probe! Adjustable emissivity! High accuracy! Fast response time! DS ratio of 75:1TKTL 11TKTL 21TKTL 31DS ratio 75:10,1–1,0EmissivityDS ratio 30:10,1–1,0EmissivityDS ratio 16:10,95Emissivity
؏؏To help ensure long bearing service life, it is important to determine the condition of machinery and bearings while in operation. Good predictive maintenance will help reduce machine downtime and decrease overall maintenance costs. SKF Infrared thermometers help analysing critical environmental conditions that have an impact on bearing and machine performance.SKF Infrared thermometers can also be used for temperature measurements in areas such asHVAC! Balance room temperatures! Monitor supply/return registers! Test ductwork! Examine stream traps! Check furnace performance! Perform energy auditsFood safety! Check cold and hot cooking, holding and serving temperatures! Helps ensure safe and uniform storage and transportation temperatures! Maintain freezers, walk-ins, ovens, ranges and dishwashersFurthermore ! Roofing, asphalt, and concrete applications! Commercial printing! Plastics moulding! Fire detection/prevention! Aviation and marine maintenanceTKTL 40Dual laser infrared and contact video thermometer! 2.2” TFT LCD display! 640 x 480 pixels digital camera! Internal memory expandable to 8 GB (Micro SD card)! Image (JPEG) and video (MP4)! Humidity and air temperature! Dual laser targeting! Type-K thermocouple probe! Adjustable emissivity! High accuracy! Fast response time! Dewpoint temperature and wet bulb temperatureTKTL 40DS ratio 50:10,1–1,0Emissivity
skf.com | skf.com/mapro | skf.com/lubrication® SKF is a registered trademark of the SKF Group. © SKF Group ؏ ؏ The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.PUB MP/P8 10845 EN · June ؏ ؏ DesignationTKTL 11TKTL 21TKTL 31TKTL 40Temperature range using infrared–6 to +625 °C (76 to +1 157°F)–6 to +76 °C (–76 to +1 400 °F)–6 to +1 6 °C (–76 to +2912 °F) –5 to +1 °C (–58 to +1 832 °F) Temperature range using probe–64 to +1 4 °C (–83 to +2 552 °F)–64 to +1 4 °C (–83 to +2 552 °F)   –5 to +1 37 °C (–58 to +2 498 °F)Probe suppliedTMDT 2-3 included (max. 9 °C (1 650 °F))TMDT 2-3 included (max. 9 °C (1 650 °F))TMDT 2-3 included (max. 9 °C (1 650 °F))Distance-to-spot ratio16:13 :175:15 :1Emissivity .95 ,1-1, ,1-1, ,1-1, Measurement accuracy+/-2% of reading or 2 °C (4°F) whichever is greater  +/-2% of reading or 2 °C (4 °F) whichever is greater+/-1% of reading or 1 °C (1.8 °F) whichever is greater+/-1% of reading or 1 °C (1.8 °F) whichever is greaterOperating temperatur to 5 °C (32 to 122 °F) 1 to 95% R.H. to 5 °C (32 to 122 °F) 1 to 95% R.H. to 5 °C (32 to 122 °F) 1 to 95% R.H. to 5 °C (32 to 122 °F) 1 to 95% R.H.Storage–1 to +6 °C (–14 to +140 °F) 1 to 95% R.H.–1 to +6 °C (–14 to +140 °F) 1 to 95% R.H.–1 to +6 °C (–14 to +140 °F) 1 to 95% R.H.–1 to +6 °C (–14 to +140 °F) 1 to 95% R.H.Response time msec1 1 1 <3 Displayed resolution .1 °C/F (below 999.9), 1° C/F (above 1 ) .1 °C/F (below 999.9), 1° C/F (above 1 ) .1 °C/F (below 999.9), 1° C/F (above 1 ) .1 °C/F (below 999.9), 1° C/F (above 1 )DisplayColour backlit LCDColour backlit LCDMonochrome backlit LCDColour backlit LCDSpectral response8-14 µm8-14 µm8-14 µm8-14 µmMeasurement modesMaximum temperaturesMaximum; Minimum; Average; Difference (between min and max); Probe/IR dual temperatureMaximum; Minimum; Average; Difference (between min and max); Probe/IR dual temperatureMaximum; Minimum; Average; Difference (between min and max); Probe/IR dual temperatureAlarm modesHigh and low level alarm with warning soundHigh and low level alarm with warning soundHigh and low level alarm with warning soundLaser8x red targeting laser dots, Class 28x red targeting laser dots, Class 22x red targeting laser dots, Class 22x red targeting laser dots, Class 2Operating timeMin. 9 hours continuous useMin. 3 hours continuous use without laserMin. 14 hours continuous use without laser and back lightMin. 4 hours continuous useMeasurement modesMax. temperaturesMax, min, differential, average, probe/IR dual temperature modesMax, min, differential, average, probe/IR dual temperature modesMax, min, differential, average, probe/IR dual temperature modesAuto switch offAutomatic, 15 seconds after trigger releaseAutomatic, 6 seconds after trigger release in IR mode and 12 minutes after trigger release in probe modeAutomatic, 6 seconds after trigger release in IR mode (6 minutes can be manually selected) and 12 minutes after trigger release in probe mode Automatic, user selectableHVAC functionalities–––Wet bulb, dew point, humidity, air temperaturePhoto and video–––64 x 48 camera, images (JPEG) and video (3 GP)Memory–––31 MB internal memory; expandable with micro SD card (8 GB max.)PC connectionMini USB port, mini USB to USB cable includedContents1x IR thermometer (TKTL 11); 2x AAA Alkaline batteries; 1x Instructions for use1x IR thermometer (TKTL 21); 1x Temperature probe (TMDT 2-3 ); 2x AAA Alkaline batteries; 1x Instructions for use; 1x Carrying case1x IR thermometer (TKTL 31); 1x Temperature probe (TMDT 2-3 ); 2x AAA Alkaline batteries; 1x Instructions for use; 1x Carrying case1x IR thermometer (TKTL 4 ); 1x Temperature probe (TMDT 2-3 ); 1x AC battery charger; 1x Mini USB to USB connection cable 1x Mini tripod 1x Instructions for use; 1x Carrying caseProduct dimensions119,2 × 171,8 × 47,5 mm (4.7 × 6.8 × 1.9 in.) 119,2 × 171,8 × 47,5 mm (4.7 × 6.8 × 1.9 in.) 2 3 × 197 × 47 mm (8.0 × 7.7 × 1.8 in.)2 5 × 155 × 62 mm (8.1 × 6.1 × 2.4 in.)Packing dimensions253 × 67 × 136 mm (9.96 × 2.64 × 5.35 in.) 53 × 85 × 18 mm (20.9 × 3.4 × 7.0 in.)53 × 85 × 18 mm (20.9 × 3.4 × 7.0 in.)53 × 85 × 18 mm (20.9 × 3.4 × 7.0 in.)Product weight (incl. batteries)255,7 g (0.56 lb)255,7 g (0.56 lb)386,1 g (0.85 lb)6 g (1.3 lb)Total weight4 g (0.88 lb)1 15 g (2.54 lb)1 3 g (2.87 lb)1 7 g (3.8 lb)Technical data
Bu ürüne ilk yorumu siz yapın!
Bu ürünün fiyat bilgisi, resim, ürün açıklamalarında ve diğer konularda yetersiz gördüğünüz noktaları öneri formunu kullanarak tarafımıza iletebilirsiniz.
Görüş ve önerileriniz için teşekkür ederiz.
TMDT2-30_STANDART YÜZEY PROBU SKF SKF.TMDT2-30
TMDT2-30_STANDART YÜZEY PROBU SKF

Tavsiye Et

*
*
*
IdeaSoft® | E-Ticaret paketleri ile hazırlanmıştır.